All Issue

2015 Vol.20, Issue 1 Preview Page
31 March 2015. pp. 65 ~ 75
Abstract
An artificial recharge test aimed at investigating transport characteristics of the injected water plume in a fractured rock aquifer was conducted. The test used an injection well for injecting tap water whose temperature and electrical conductivity were different from the groundwater. Temporal and depth-wise variation of temperature and electrical conductivity was monitored in both the injection well and a nearby observation well. A highly permeable fracture zone acting as the major pathway of groundwater flow was distinctively revealed in the monitoring data. A finite element subsurface flow and transport simulator (FEFLOW) was used to investigate sensitivity of the transport process to associated aquifer parameters. Simulated results showed that aperture thickness of the fracture and the hydraulic gradient of groundwater highly affected spatio-temporal variation of temperature and electrical conductivity of the injected water plume. The study suggests that artificial recharge of colder water in a fractured rock aquifer could create a thermal plume persistent over a long period of time depending on hydro-thermal properties of the aquifer as well as the amount of injected water.

References
  1. Banks, D., 2008, An introduction to thernogeology : Ground source heating and cooling, Wiley-Blackwell, Oxford, pp. 339.
  2. Bouwer, H., 2002, Artificial recharge of groundwater : Hydrogeology and engineering, J. Hydrogeol., 10, 121-142.10.1007/s10040-001-0182-4
  3. Chang, S. and Chung, I., 2014, Analysis of Groundwater Variations using the Relationship Between Groundwater use and Daily Minimum Temperature in a Water Curtain Cultivation Site, J. of Engineering Geol., 24(2), 217-225.10.9720/kseg.2014.2.217
  4. Gelhar, L.W., Welty, C., and Rehfeldt, K.R., 1992, A critical review of data on field-scale dispersion in aquifers, Water Resour. Res., 28(7), 1955-1974.10.1029/92WR00607
  5. Kim, H., Kim, M., and Suk, H., 2005, Assesment of storage property of fractured rock aquifer by the artificial recharge method, J. of the Geological Society of Korea, 41(3), 415-426.
  6. Kim, N., Lee, J., Chung, I., and Kim, C., 2012, Change of Groundwater-Streamflow Interaction according to Groundwater Abstraction in a Green House Land, J. Korea Water Resources Association, 45(10), 1051-1067.10.3741/JKWRA.2012.45.10.1051
  7. Lee, H., Koo, M., and Kim, Y., 2014, Determining Optimal Locations of an Artificial Recharge Well using an Optimizationcoupled Groundwater Flow Model, J. Soil & Groundwater Env., 19(3), 66-81.10.7857/JSGE.2014.19.3.066
  8. Lopez, D.L. and Smith, L., 1995, Fluid flow in fault zones : Analysis of the interplay of convective circulation and topographically driven groundwater flow, Water Resour. Res., 31(6), 1489-1503.10.1029/95WR00422
  9. MOLIT (Ministry of Land, Infrastructure and Transport), 2013a, Annual report for groundwater development, utilization, and monitoring, 136 p.
  10. MOLIT (Ministry of Land, Infrastructure and Transport), 2013b, Report on groundwater basic survey of Kongju area.
  11. MOLTMA (Ministry of Land, Transport and Maritime Affairs), 2008, Annual report for groundwater development, utilization, and monitoring, 154 p.
  12. Oh, J., 2014, Modeling groundwater temperature in the artificial recharge system: Sensitivity analysis, Master thesis, Kongju National University, Korea.
  13. Oh, S., Koo, M., and Kim, Y., 2011, Modeling the artificial recharge in reservoir of Hanchun drainage area, Jeju island in Korea, KSEG Conference, 16(6), 34-45.
Information
  • Publisher :The Korean Society of Soil and Groundwater Environment
  • Publisher(Ko) :한국지하수토양환경학회
  • Journal Title :Journal of Soil and Groundwater Environment
  • Journal Title(Ko) :지하수토양환경
  • Volume : 20
  • No :1
  • Pages :65 ~ 75